250 hour, Drilling unit – Ditch Witch JT100AT User Manual
Page 210

JT100/JT100 All Terrain Operator’s
Manual
Service - 209
250 Hour
CMW
©
250 Hour
Drilling Unit
Change Engine Oil and Filter (initial)
Change engine oil and filter after 250 hours. If
using motor oil that does not meet Deutz
specifications DQCIII-LA, regular change interval
will be 250 hours. See page 185 for more
information about DEO specifications.
To change:
1.
While oil is warm, remove drain plug (2).
Drain oil and replace plug.
2.
Remove filter (3) and replace with new filter
each time oil is changed. Add DEO at fill (1).
Change JT Drilling Fluid Planetary Oil
Change every 250 hours. Remove oil at fill (1).
Add MPL until oil comes out level plug (2).
Replace plugs.
Location
Task
Notes
DRILLING
UNIT
Change engine oil and filter
initial service
Change JT drilling fluid planetary oil
MPL
LOADER/
DRIVER
Check swing drive gearbox oil level
MPL
IMPORTANT: Use oil specified in temperature chart found in “Recommended Lubricants/Service Key”
on page 188.