Startup/10 Hour
CMW
©
Check Pipe Auto Lubricator Spray
Nozzle
Check pipe auto lubricator spray nozzle before
startup and every 10 hours of operation. Ensure
that nozzle is free of obstructions and operates
properly. Clean as needed.
To clean:
1.
Rotate handle to the upward, or cleanout, position (A).
2.
Operate pump until obstruction is flushed.
3.
Rotate handle to the downward, or spray, position (B).
4.
Clean nozzle guard. If necessary, pull handle/nozzle insert out of housing to clean with fine wire or
solvent.
Check Pipe Auto Lubricator TJC Level
Check pipe auto lubricator TJC level before
startup and every 10 hours of operation. Change
pail as needed. See “Change Auto Lubricator
TJC Pail” on page 224 for procedure
NOTICE: Ditch Witch
®
tool joint compound is
specially formulated to work with Ditch Witch
pipe lubrication system. Use of other tool joint
compounds will clog system. See
“Recommended Lubricants/Service Key” on
page 188 for more information.
NOTICE: Ditch Witch tool joint compound is
specially formulated to work with Ditch Witch
pipe lubrication system. Use of other tool joint
compounds will clog system. See
“Recommended Lubricants/Service Key” on
page 188 for more information.