Troubleshoot strike system, Jt30 /jt30 all terrain operator’s manual – Ditch Witch JT30AT User Manual
Page 134
JT30 /JT30 All Terrain Operator’s Manual
Systems and Equipment - 134
Electric Strike System
CMW
Troubleshoot Strike System
When strike system detects a problem, a diagnostic code will be displayed. Anytime this happens, go to
the ESID menu and select test function to retest. If a diagnostic code is still displayed and does not appear
in this chart, have control module checked or replaced.
Other problem situations and their possible causes and solutions are listed in the chart below.
Problem
Possible cause
Possible solution
V and A flashing on
Information Center ESID
display
Problems in startup
Go to ESID menu and select test
function. If problem goes away, retest
strike system
No power to strike system
control module
Check drilling unit electrical system
Check that harness from drilling unit
to control module is connected
Check that cable from drilling unit
carries more than 10V
Defective control module
Have control module checked or
replaced
Defective CAN bus connection
Ensure CAN cable from drilling unit to
ESID control module is connected
dc513 Test Wire shows on
Information Center
Test wire not connected
Check that test wire is connected to
ESID control module
Check that test wire is connected to
Information Center
Have ESID control module checked
or replaced
Strobe light on drilling unit
does not work during total
test
Improper connections with
control module
Check connections and wiring
harness
Defective strobe light
1.
Disconnect strobe and connect to
external 12V power source.
2.
If alarm does not work, replace it.
Defective control module
Have control module checked or
replaced
Alarm on drilling unit does
not work during total test
Improper connections with
control module
Check connections and wiring
harness
Defective alarm
1.
Disconnect alarm and connect to
external 12V power source.
2.
If strobe does not work, replace it.
Defective control module
Have control module checked or
replaced