beautypg.com

Toa S-D7802 User Manual

Page 26

background image

26

11.2. Termination Impedance Setting of the word Clock Input

Input impedance for the coaxial cable input of the external word clock can be selected.

Use rear-mounted terminal selector switch to select "Open" or "75 Ω."

Notes

• When using the word clock distributor

Connect the word clock signal to be output from the word clock generator to the receiver's word clock input

terminal in a one-to-one relationship via the dedicated distributor.

In this event, set each receiver's terminal selector switch to "75 Ω."

Word clock

generator

S-D7802 (1)

Word clock input

TERM: 75 Ω

S-D7802 (2)

Word clock input

TERM: 75 Ω

S-D7802 (3)

Word clock input

TERM: 75 Ω

Word clock

distributor

BNC coaxial cable

• When making a daisy chain connection

In the case of a daisy chain connection, signals from the word clock generator are distributed to the next

device one after another by using the commercially available T-shaped BNC connectors.

In this event, set the terminal switch of only the last connected receiver to "75 Ω" and other receivers' switches

to "OPEN."

This distribution connection method is not recommended for the large system.

TERM

75Ω

OPEN

OCK

Word clock

generator

S-D7802 (1)

Word clock input

TERM: OPEN

S-D7802 (2)

Word clock input

TERM: OPEN

S-D7802 (3)

Word clock input

TERM: 75 Ω

T-shaped BNC connector