Creating a controller for application control, Press the setup key to display the following, Press the app rate config key. 4 – TeeJet LH665 VRT User Manual
Page 37

LH 665 VRT O
PERATORS MANUAL
A
PPLICATION CONTROL
,
ENCODE
&
CALIBRATION
LH A
GRO
4.3
CREATING A CONTROLLER FOR APPLICATION CONTROL
The following procedure should be followed to "create" an implement controller in
the LH 665:
Step Key
Procedure
1
Press the MENU key until the following menu selection keys
appear at the bottom of the display (screen section C):
CAL
SETUP
DIAG
2
SETUP
Press the SETUP key to display the following:
APP RATE
CONFIG
MARKS
CARD
LOAD
3
APP RATE
CONFIG
Press the APP RATE CONFIG key.
4
CREATE
NEW
Press the CREATE NEW key and the following is displayed:
EXIT
EDIT
APP RATE CONFIG
Controller Make
LH AGRO
Controller Model
LH 5000
Product PRODUCT
1
Units KG
Ground Speed Sensor
GPS
App Distance From GPS
0 ft fwd
Full Swath
From Controller
Tgt Units:Controler Units
1:1.0000
Target Rate Increment
1.0
Actual Rate Scale Factor
1.000
Use the ARROW UP/DOWN keys to highlight the required
encodement.
5
EDIT
Press the EDIT key and select the required value using the
ARROW UP/DOWN keys.
6
ADVANCED
SETTINGS
Press the ADVANCED SETTINGS key to alter any of the
advanced settings described on page 4.5.
Controller Make/Model:
Select LH AGRO as the Controller Make and LH 5000 as the Controller
Model.
Product:
Select the product to be used. The name of the product can be edited in the
second screen that appears when the EDIT key has been pressed.