Function keys, Target rate actual rate area – TeeJet LH665 VRT User Manual
Page 26

A
PPLICATION CONTROL
,
OPERATION
LH 665 VRT O
PERATORS MANUAL
3.10
LH A
GRO
FUNCTION KEYS
All function keys are displayed in the following manner:
Step Key
Procedure
1
Screen section B is split up in four sub-sections. Each sub-
section has a corresponding function key to the right of the
screen.
Press one of the function keys to highlight one of the sub-
sections.
2
Pressing the lower ARROW keys whilst the sub-section is
highlighted displays the available function keys. Pressing one
of these keys will change the function to the selected and the
display will return to normal.
TARGET RATE
Step Key
Procedure
1
TARGET
RATE
XX.XX x/ha
The target rate for the present position in the field. This can
be set to automatic (where the amount to be applied is taken
from the target file selected) or manual (where the amount to
be applied can be manually adjusted in steps, the size of the
steps is encoded as described on page 4.4).
Select between automatic or manual target rate using the
LEFT/RIGHT ARROW keys.
ACTUAL RATE
Step Key
Procedure
1
ACTUAL
RATE
XX.XX x/ha
The actual rate (from the controller). When the implement
sensor is active (not counting area) the average rate is
displayed.
AREA
Step Key
Procedure
1
AREA
XX.XXX ha
The worked area for the present field or load.