beautypg.com

Operation, Setting the lh 665 to application control – TeeJet LH665 VRT User Manual

Page 19

background image

LH 665 VRT O

PERATORS MANUAL

A

PPLICATION CONTROL

,

OPERATION

LH A

GRO

3.3

OPERATION

SETTING THE LH 665 TO APPLICATION CONTROL

The LH 665 may need setting up for application control. The following procedure
sets the computers “operating mode”.

Step Key

Procedure

1

Press the MENU key until the following menu selection keys
appear at the bottom of the display (screen section C):

CAL

SETUP

DIAG

2

SETUP

Press the SETUP key to display the following:

SWATH

MARKS

CROP

CARD

3

Press the lower ARROW keys until the following is displayed:

LOAD

VEHICLE

MEMORY

CONSOLE

4

CONSOLE

Press the MONITOR key and this screen is displayed:

EXIT

EDIT

CONSOLE SETUP

Operating Mode

APPLICATION RATE

Day/Month/Year 1/06/1999

Time 11:23

Serial Number

9800085

Box cal.

774

Voltage cal.

487

GPS Check Sum

OFF

Field Marker input

INTERNAL

Use the ARROW UP/DOWN keys to highlight Operating

Mode.

5

EDIT

Press the EDIT key and select APPLICATION RATE
using the ARROW UP/DOWN keys.

6

ACCEPT

When APPLICATION RATE has been selected under

Operating Mode press the ACCEPT key.