Electrical components 4, Limit control 4, Relay 4 – Reznor SSCDBL Parts Manuals User Manual
Page 4: Erminal block 4, Ransformer 4

Form P-SC, P/N 269822R3, Page 4
Code 14 - Time
Delay Relay ,
P/N 259780
Code 16 - SPDT Relay, RBM
84-20103-301, P/N 18549
Locations - Control Side
(See parts illustrated on pages 4-7.)
Codes 12A and 12B
Terminal Block,
P/N 144972
Terminal Block
Adapter,
P/N 144973
Code 13 -
Control and
Damper
Transformers
1
3
5
4
2
Same as Option BG3
& part of Option BG5
Code 21A - Limit Controls used on
Model SSCBL mfgd beginning 1/97
(for older units, see below)
"BL" Blower
Cabinet
Air Flow
Furnace
#1
Furnace
#2
Furnace
#3
Automatic Reset Limit
Control with Linear
Sensor, TOD #10HG11,
P/N 148588
Automatic Reset
Limit Control,
TOD #60T11
Code 21B - Limit Controls and
Shields used on Model Series
SSCBL mfgd prior to 1/97
Automatic
Reset Limit
Control,
TOD
#60T11
Furnace Size 400
Sizes 500/600/800
Sizes 1050/1200
#1
50418, 145°F
50418, 145°F
50417, 125°F
148588, TOD #10HG11
#2
57953, 170°F
50418, 145°F
148588, TOD #10HG11
#3
57953, 170°F
148588, TOD #10HG11
P/N 12229 P/N 9704
Limit Shields
Key: (Applies to both limit tables)
Code 20A - Limit Control
Code 20B - Limit
Control Shield,
P/N 9704
Code 19 - Time Delay
Relay, T & B Agastat
TM1ULA, P/N 89661
Used in freezestat circuit;
used in Option AG39 and
AG40 prior to 7/00
Code 18 - Time Delay Relay,
SPDT, 24V, Thermodisc
12S30, P/N 174810
Used in
Option AG39
and AG40
Code 17 - Relay, P/N
211411 and P/N 211415
P/N 50417, opens 125°F;
closes 105°F
13 - Transformer
40VA
12 - Terminal
Blocks
17 - Relay,
(Opts 8, 9,
AG21)
18 - Time
Delay Relay
(Opts AG
39, 40)
15 - Fan Time
Delay Relay
23 - Venter
Pressure Switch
27 - Firestat
(Opts BD 2, 3)
22 - Ignition Controller
20, 21 - Limit Control
41 & 42 - Low
Gas Pressure
Switch (Opt BP4)
43 - High Gas
Pressure Switch
(Opt BP4)
14 - Venter Time
Delay Relay
Venter
Assy
Burner Rack
and Manifold
25 - Air Flow
Proving
Switch (Opt BW1)
Location of 32 - Signal
Conditioner (Opt AG21);
39 - Amplifier (Opt AG7,8,9);
or 29 - Ductstat (Opt AG3)
P/N 103054, 115/24/20VA,
Basler #BE121625-WAR
P/N 103055, 115/24/40VA, Basler
#BE141650-WAA
P/N 103497, 208/230/24/40VA,
Basler #BE2153900
P/N 103498, 460/24/40VA, Basler
#BE23975001
Code 15 - SPST Time Delay Relay
(fan/blower control on units mfgd
beginning 12/04), P/N 209164,
Thermodisc I2S20-305131
For units manufactured prior to 12/04, the
temperature activated fan control is no longer
available. Order Replacement Kit,
P/N 209184
.
To replace time delay relay (P/N
46233 or 259518) used on product
manufactured prior to 2/2010,
order replacement kit,
P/N 259521.
For units manufactured
prior to 9/2011, order
a replacement kit,
P/N
263527, to replace relay
14747, 98118. or 103317
Furnace
Size 400
Sizes 500/600/800
Sizes 1050/1200
#1
50418, 145°F
50418, 145°F
50417, 125°F
12229, Limit Shield
12229, Limit Shield
#2
57953, 170°F
19080, 155°F
9704, Limit Shield
#3
57953, 170°F
Limit Control and
Limit Shield for SC
Series 6
Electrical Components