Page 4: Erminal block 4, Ransformer 4

background image

Form P-SC, P/N 269822R3, Page 4

Code 14 - Time

Delay Relay ,

P/N 259780

Code 16 - SPDT Relay, RBM

84-20103-301, P/N 18549

Locations - Control Side

(See parts illustrated on pages 4-7.)

Codes 12A and 12B

Terminal Block,

P/N 144972
Terminal Block

Adapter,

P/N 144973

Code 13 -

Control and

Damper

Transformers

1

3

5

4

2

Same as Option BG3

& part of Option BG5

Code 21A - Limit Controls used on

Model SSCBL mfgd beginning 1/97

(for older units, see below)

"BL" Blower

Cabinet

Air Flow

Furnace

#1

Furnace

#2

Furnace

#3

Automatic Reset Limit

Control with Linear

Sensor, TOD #10HG11,

P/N 148588

Automatic Reset

Limit Control,

TOD #60T11

Code 21B - Limit Controls and

Shields used on Model Series

SSCBL mfgd prior to 1/97

Automatic

Reset Limit

Control,

TOD

#60T11

Furnace Size 400

Sizes 500/600/800

Sizes 1050/1200

#1

50418, 145°F

50418, 145°F

50417, 125°F

148588, TOD #10HG11

#2

57953, 170°F

50418, 145°F

148588, TOD #10HG11

#3



57953, 170°F

148588, TOD #10HG11

P/N 12229 P/N 9704

Limit Shields

Key: (Applies to both limit tables)

Code 20A - Limit Control

Code 20B - Limit

Control Shield,

P/N 9704

Code 19 - Time Delay

Relay, T & B Agastat

TM1ULA, P/N 89661

Used in freezestat circuit;

used in Option AG39 and

AG40 prior to 7/00

Code 18 - Time Delay Relay,

SPDT, 24V, Thermodisc

12S30, P/N 174810

Used in

Option AG39

and AG40

Code 17 - Relay, P/N

211411 and P/N 211415

P/N 50417, opens 125°F;

closes 105°F

13 - Transformer

40VA

12 - Terminal

Blocks

17 - Relay,

(Opts 8, 9,

AG21)

18 - Time

Delay Relay

(Opts AG

39, 40)

15 - Fan Time

Delay Relay

23 - Venter

Pressure Switch

27 - Firestat

(Opts BD 2, 3)

22 - Ignition Controller

20, 21 - Limit Control

41 & 42 - Low

Gas Pressure

Switch (Opt BP4)

43 - High Gas

Pressure Switch

(Opt BP4)

14 - Venter Time

Delay Relay

Venter

Assy

Burner Rack

and Manifold

25 - Air Flow

Proving

Switch (Opt BW1)

Location of 32 - Signal

Conditioner (Opt AG21);

39 - Amplifier (Opt AG7,8,9);

or 29 - Ductstat (Opt AG3)

P/N 103054, 115/24/20VA,

Basler #BE121625-WAR

P/N 103055, 115/24/40VA, Basler

#BE141650-WAA

P/N 103497, 208/230/24/40VA,

Basler #BE2153900

P/N 103498, 460/24/40VA, Basler

#BE23975001

Code 15 - SPST Time Delay Relay

(fan/blower control on units mfgd

beginning 12/04), P/N 209164,

Thermodisc I2S20-305131

For units manufactured prior to 12/04, the

temperature activated fan control is no longer
available. Order Replacement Kit,

P/N 209184

.

To replace time delay relay (P/N

46233 or 259518) used on product

manufactured prior to 2/2010,

order replacement kit,

P/N 259521.

For units manufactured

prior to 9/2011, order

a replacement kit,

P/N

263527, to replace relay

14747, 98118. or 103317

Furnace

Size 400

Sizes 500/600/800

Sizes 1050/1200

#1

50418, 145°F

50418, 145°F

50417, 125°F

12229, Limit Shield

12229, Limit Shield

#2

57953, 170°F

19080, 155°F

9704, Limit Shield

#3

57953, 170°F

Limit Control and

Limit Shield for SC

Series 6

Electrical Components