Product update bulletin, Old pcm display new pcm display – Proheat X45–School Bus User Manual
Page 113

© 2009 Marine Canada Acquisition Inc. DBA SEASTAR SOLUTIONS 3831 No. 6 Road, Richmond, B.C. Canada V6V 1P6
Tel: 604.270.6899
Web: www.proheat.com
PRODUCT UPDATE BULLETIN
Copy Part# PB0034, Rev. B, 04/2009
Page 2 of 3
1
100 % Backward Compatible
• G-III PCM works with existing heaters and wiring harnesses.
2
CANbus Communication and new Serial Port Location
• The new communication port provides CANbus SAE J-1939 communication.
• Relocated serial port allows Datalink connection without disconnecting
the switch input.
• New communication port requires the G-III controller Proheat Data Link
Kit PK0053-3. The G-II download cable kit PK0053-2 (download cable
and software) will not work with the G-III controller.
3
New 2x7 Segment LED
• The 2x7 segment LED provides improved communication of operational
states and error messages.
• Figure 2: Original G-II PCM display with single LED lamps and new G-III PCM
display with 2x7 segment LEDs.
• Figure 3: Original G-II PCM code numbers still apply. For example,
Diagnostic Code LED associated with 12 Blower on the original PCM
display will light up as the number 12 on the new display. In addition,
the G-III controller indicator switch lamp will blink 12 times like the G-II
controller does.
• Figure 3: Also illustrated is the “ON” indicator meaning the heater is
powered in the normal or standby state and “Pu” indicator showing the
heater is in the Cool Down (Purge) state.
• X45 ONLY: A new error code, 14, has been added to indicate a short
circuit on the hour meter (auxiliary output) harness. For this error code,
the indicator switch lamp will blink 14 times as well.
Figure 2: Comparison of the original G-II PCM to the new G-III PCM display.
OLD PCM DISPLAY
NEW PCM DISPLAY