Appendix B: EIU troubleshooting 115

DMS-100 Family EIU User Guide TELECOM12

Cannot set up an FTP session between a SuperNode-based
node and an external node

4, 8

Cannot ping between two SuperNode-based nodes

4, 5

Cannot set up an TCP connection between two SuperNode-
based nodes

4, 5, 6

Cannot log in as the admin user

7, 8

Cannot setup an FTP session between two SuperNode-
based nodes

4

Can ping EIU, but cannot ping the computing module (CM)

4

1

There are no EIUs in service.

2

Table IPNETWRK is not datafilled.

3

Table IPROUTER is not datafilled or does not contain the in-service EIU as
one of its entries.

4

Table IPHOST for the node in question is not datafilled with non-zero values.

5

Table IPTHRON contains zero values.

6

Someone else is logged on to the server with the same userID.

7

The system permits only one FTP session at a time for the admin user.

8

There are no TCP resources.

Table 30

EIU troubleshooting checklist (continued)

Problem

Probable cause

(Sheet 2 of 2)