GTCO Cordless Roll-Up - Users Guide User Manual
Page 41
Cordless Roll-Up 41
Set Digitizing Rate
Code: Rx
Coordinates can be sent from the Cordless Roll-Up at rates from 5 to 140 coordinates per
second. The second character in this command sets the rate, as shown in the table below.
Actual rates are limited by the communication baud rate and coordinate type you have
selected. The rates shown here are, therefore, maximum rates.
Rate Commands
Digitizing rate, formats/second
Digitizing rate command
12 100 100 5 10 50
R1 R2 R3 R4 R5 R6
Change Mode Character
Code: MC
Some applications may have a predefined meaning for the SOH (CTRL-A) character used to
invoke Command Mode. If so, invoking Command Mode may cause your system to do
something else. You can set the Cordless Roll-Up so that a character other than SOH is
used to begin Command Mode. Here is how to make the substitution:
1. Enter Command Mode.
2. Send MC, followed by a
ENTER NEW COMMAND MODE CHARACTER:.
3. Enter the desired mode change character. The new mode character can be any
character except ESC (CTRL-[, hex 1B),
VT (CTRL-K, hex 0B), XON (CTRL-Q, hex 11) or XOFF (CTRL-S, hex 13).
Now, when you want to enter the Command Mode, send the new character. All other
command operations remain unchanged.
Select English Measurement Scale
Select Metric Measurement Scale
Code: IN
Code: MT
Invoking these commands causes the Cordless Roll-Up to scale coordinates in the desired
measurement system. The Cordless Roll-Up measures in only one scale at a time. See
Measurement Scales for additional information on how scale selection affects coordinate
data.
Enable Echo Mode
Disable Echo Mode
Code: EM
Code: hex 0F (Ctrl-O)
These commands control echoing by the Cordless Roll-Up. When enabled, echoing
transmits each received character back to the sending device.