Comtrol AT Commands for SmartACFL User Manual
Page 91
Command Reference Manual
100722A
Conexant
3-71
3.3.3.23 S26 - RTS to CTS Delay
S26 sets the time delay, in hundredths of a second, before the modem turns CTS ON after detecting an OFF-to-ON transition
on RTS when &R0 is commanded. Pertains to synchronous operation only.
Range:
0-255 hundredths of a second
Default: 1
3.3.3.24 S27 - Bit Mapped Options Status
S27 indicates the status of command options.
Default: 73 (49h) (01001001b)
Bits 0,1,3
Synchronous/asynchronous selection (&Mn/&Qn)
3
1
0
0
0
0
=
&M0 or &Q0
0
0
1
=
&M1 or &Q1
0
1
0
=
&M2 or &Q2
0
1
1
=
&M3 or &Q3
1
0
0
=
Reserved
1
0
1
=
&Q5 (Default.)
1
1
0
=
&Q6
Bit 2
Leased line control (&Ln)
0 =
Dial up line (&L0) (Default.)
Bits 4 - 5
Internal clock select (&Xn)
0 =
Internal clock (&X0) (Default.)
1 =
External clock (&X1)
2 =
Slave clock (&X2)
Bit 6
CCITT/Bell mode select (Bn)
0 =
CCITT mode (B0)
1 =
Bell mode (B1) (Default.)
Bit 7 - Reserved
3.3.3.25 S28 - Bit Mapped Options Status
S28 indicates bit mapped options status.
Default: 0
Bits 0 - 1
Reserved
Bit 2
Reserved (always 0).
Bits 3 - 4
Pulse dialing (&Pn)
0 =
39%-61% make/break ratio at 10 pulses per second (&P0) (Default.)
1 =
33%-67% make/break ratio at 10 pulses per second (&P1)
2 =
39%-61% make/break ratio at 20 pulses per second (&P2)
3 =
33%-67% make/break ratio at 20 pulses per second (&P3)
Bit 5-7
Reserved