Comtrol AT Commands for SmartACFL User Manual
Page 133

Command Reference Manual
100722A
Conexant
5-11
5.3.7
+FCIG - Set Polling ID
This command allows setting the Local Polling ID string used in a CIG frame. The syntax of this command is identical to
+FLID.
Write syntax:
+FCIG="
Valid value:
20-character ASCII string
Default value:
Empty
5.3.8
+FLPL - Indicate a Document for Polling
This command allows setting up an answering modem to know that it has a document available for polling. This allows a
calling modem to receive this fax from the answerer. The syntax is:
AT+FLPL=?
0,1
OK
AT+FLPL=1
OK
AT+FLPL?
1
5.3.9
+FSPL - Enable Polling
This command allows setting up an originating modem to be able to request to receive a document from a polled station. The
syntax is:
AT+FSPL=?
0,1
OK
AT+FSPL=1
OK
AT+FSPL?
1
This manual is related to the following products: