Command Reference Manual
3-10
Conexant
100722A
3.2.1.17 &W - Store Current Configuration
Saves the current (active) configuration (profile), including S-Parameters, in one of the two user profiles in NVRAM as
denoted by the parameter value. This command will yield an ERROR message if the NVRAM is not installed or is not
operational as detected by the NVRAM test.
The current configuration is comprised of a list of storable parameters illustrated in the &V command. These settings are
restored to the active configuration upon receiving a Zn command or at power up (see &Yn command).
Syntax
&W
Defined Values
Decimal number corresponding to the selected profile.
0
Store the current configuration as profile 0.
1
Store the current configuration as profile 1.
Result Codes
OK
ERROR
Otherwise.
3.2.1.18 &Zn=x - Store Telephone Number
The modem can store up to four telephone numbers and each telephone number dial string can contain up to 31 digits.
(Requires 256-byte NVRAM installed.)
Syntax
&Z
Defined Values
Decimal number from 0 to 3 corresponding to the selected telephone number.
Dial string from 0 to 31 characters.
Result Codes
OK
For
≤ 3, and
ERROR
If
3.2.1.19 %7 - Plug and Play Serial Number
Sets and stores eight serial numbers in hex format used for serial Plug and Play and for ISA Plug and Play which use the
Conexant 11596 Plug and Play device. Applicable to Desktop configuration only.
Syntax
%7<8 hex numbers>
Example
%7<8 hex numbers>
Result Codes
OK
<8 hex numbers>
ERROR
Otherwise
To display the stored serial number, issue AT"?