3.2.1.14 &F - Restore Factory Configuration (Profile)
The modem loads the factory default configuration (profile). The factory defaults are identified for each command and in the
S-Parameter descriptions. A configuration (profile) consists of a subset of S-Parameters.
Syntax
&F[
Defined Values
Decimal number corresponding to the selected configuration.
0
Restore factory configuration 0.
1
Restore factory configuration 1.
Result Codes
OK
ERROR
If the modem is connected.
3.2.1.15 &T - Local Analog Loopback Test
The modem will perform the local analog loopback test if &T1 is selected. The test can be run only when in an asynchronous
operation in non-error-correction mode (normal), e.g., AT&Q6. To terminate the test in progress, the escape sequence must
be entered first (see Section 3.1.1).
Syntax
&T[
Defined Values
Decimal number corresponding to the selected option.
0
Terminates test in progress. Clears S16.
1
Initiates local analog loopback, V.54 Loop 3. Sets S16 bit 0. If a connection exists
when this command is issued, the modem hangs up. The CONNECT XXXX
message is displayed upon the start of the test.
3.2.1.16 &Y - Designate a Default Reset Profile
This command selects which user profile will be used after a hard reset.
Syntax
&Y
Defined Values
Decimal number corresponding to the selected profile.
0
The modem will use profile 0.
1
The modem will use profile 1.
Result Codes
OK
ERROR
If