Group scan, All-channel scan, Memory channel lock-out – Kenwood TM-255E User Manual
Page 37: Zi i, O.u / 1 n n, 6 scan, 5 5 u zi, Zi i?s, Li. li
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Memory Scan can be used to scan only a specific
channel group (Group Scan), or to scan all memory
channels containing data (All-channel Scan).
Selection of the desired method is via Menu A, No. 05
{page 13). The default is Group Scan (OFF).
GROUP SCAN
There are 100 memory channels total, divided into
groups of 10 channels each (00 to 09,10 to 19...... 90
to 99). When Group Scan is selected, the transceiver
scans only memory channels that belong to the
specified group and contain data.
1 Press [MR] to select Memory Recall.
• The last memory channel selected appears.
2 Select any memory channel belonging to the
desired group using microphone [UP] or [OWN].
6 SCAN
MEMORY SCAN
u zi zi I
I n n
P I
I J J. I I U. LI
20
40d6
8
10
Adjust the SQL control while no signal is present.
• Remember, Menu A, No. 05 must be ON.
Press [SCAN].
• The scan speed appears with "SCAN", and
scan starts.
• To change the scan direction, turn the
Alternate Tuning control clockwise or
counterclockwise.
/
- +
M. CH
5 5
U Zi
c
1 J
Jf.
zi I
J 1
n n n 1
U. LI
P 1
USB
S
1 3 5 7 9
20 40d8
V
2 4 6
8 10
SCAN
J
4 Press [SCAN], [CLR], or the microphone [PTT] to
stop Scan.
• Memory Recall is restored.
5 To restore VFO mode, press [A/B].
Note: If no data is stored in the memory channels, or all memory
channels are locked out, pressing [SCAN] will sound the Morse
code "CHECK" reminder.
3 Adjust the SQL control while no signal is present.
4 Press [SCAN].
• The scan speed appears with "SCAN", and
Scan starts.
• To change channel groups while scanning,
press microphone [UP]/[DWN].
• To change the scan direction, turn the
Alternate Tuning control clockwise or
counterclockwise.
r "
Ij
ZI
I?S' /
J
C n
o.u
/
1
n n
„ , ™
LI. LI
P 1
SI 3 5
a
20
40dB
1
_______________ 5_____ 1_
6 8
10
SCAN j
5 Press [SCAN], [CLR], or the microphone [PTT] to
stop Scan.
• Memory Recall is restored.
6 To restore VFO mode, press [A/B].
Note: If no data is stored in the memory channels of the specified
group, or all memory channels are locked out, pressing [SCAN] will
sound the Morse code "CHECK" reminder.
ALL-CHANNEL SCAN
The All-channel Scan function scans all memory
channels containing frequency data.
1 Press [MR] to select Memory Recall.
• The last memory channel selected appears.
M. CH
/
C
/
LI
U
Zi
n n c
n n
1 J LI, 1 J
LI, LI
USB
\____
S 1 3 5 7 9 20 40dB
2 4 6 8 to
>
MEMORY CHANNEL LOCK-OUT
Memory channels that you prefer not to monitor while
scanning can be locked-out. Lock-out any memory
channel with the following procedure:
1 Press [MR] to select Memory Recall.
2 Select the memory channel to be locked-out using
the Alternate Tuning control or microphone
[UP]/[DWN].
>
M.
CH .
1
1 o 1
ZI ZI u ZI n n
Jf L. 1 C LI, LI
USB
S 1 3
5 7 9 20 40dB
1 2
4 6 8 10
J
3 Press [CLR].
A dot appears beside the memory channel
number to indicate the channel has been
locked-out.
Pressing [CLR] for more than 2 seconds erases
the contents of the memory channel.
r
---------- >1
M. CH
i o
1 a.
u
1
ZI ZI
Jf L .
u
1
ZI n n
C LI, LI
USB
s
1 3
5 7 9
20
40dB
V
2
4 6
8
10
J
4 To restore the VFO, press [A/B].
• The dot disappears.
Lock-out for an individual channel can be canceled by
repeating the above procedure.
30