Output – KEYENCE DL-PN1 User Manual
Page 8
6
- PROFINET Communication Unit DL-PN1 User's Manual (GT) -
*
"a" represents a Slot number. When Addresses were assigned in order, the Address
for Slot 1 is 16, 17, 18, or 19 to 22.
Data I/O communication device map (PROFINET I/O controller DL-PN1)
DL-PN1 (Slot 0)
Output
17+7(a-1)*
0
Reserved for system
-
-
1
Comparator value invalid
Stores the comparator value status.
0: Normal
1: Comparator value invalid
“----”
2
Comparator value under range Stores the comparator value status.
0: Normal
1: Comparator value under
range “-FFFF”
3
Comparator value over range
Stores the comparator value status.
0: Normal
1: Comparator value over
range “FFFF”
4
Reserved for system
-
-
5
Reserved for system
-
-
6
Reserved for system
-
-
7
Error status
Stores the error status of the sensor
amplifiers.
"Types of error and error code"
0: No error occurred.
1: Error occurred.
18+7(a-1)*
0
External input response 1
Stores the external input response
to the sensor amplifier.
0: No input
1: Input reception
1
External input response 2
Stores the external input response
to the sensor amplifier.
0: No input
1: Input reception
2
External input response 3
Stores the external input response
to the sensor amplifier.
0: No input
1: Input reception
3
Reserved for system
-
-
4
Reserved for system
-
-
5
Reserved for system
-
-
6
Reserved for system
-
-
7
Reserved for system
-
-
19+7(a-1)* to
22+7(a-1)*
0 to 7 Comparator value
Used when reading the comparator
value (P.V. value).
INT32
Address
Bit
Function name
Description
Value
Address
Bit
Function name
Description
Value
0
0
External input request 1
*1
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
1
External input request 2
*1
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
2
External input request 3
*1
Requests the external input to the
sensor amplifiers.
0: OFF
1: ON
3
Reserved for system
-
-
4
Reserved for system
-
-
5
Reserved for system
-
-
6
Reserved for system
-
-
7
Reserved for system
-
-