beautypg.com

Access address (slot 1 to 10) – KEYENCE DL-PN1 User Manual

Page 16

background image

14

- PROFINET Communication Unit DL-PN1 User's Manual (GT) -

Access Address (Slot 1 to 10)

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value

0

Reserved for system

1

Preset request

DINT

C

2

Preset reset request

DINT

C

3

Reset request

DINT

C

4

Error clear

DINT

C

5

Initialize request

DINT

C

6 to 31

Reserved for system

32

Group1 Entry Count

DINT

R

9

33

Sensor amplifier error state

*1

DINT

R

-

Bit0: Overcurrent error (ErC)
Bit1: Head error (ErH)
Bit2: EEPROM error (ErE)
Bit3: Jam check error (Er.chK)
Bit4: Self-timing delay error

(Er.dLY)

Bit5: Number-of-units error

(Er.Unit)

Bit6: Calculation error (Er.CAL)

34 to 35 Reserved for system

36

Control output

*2

DINT

R

Bit0: HIGH
Bit1: LOW
Bit2: GO

37

Comparator value (P.V. value)

*3
*4

DINT

R

38

Raw value (R.V. value)

*3

DINT

R

39

Peak value during sampling

*3
*4
*5

DINT

R

40

Bottom value during sampling

DINT

R

41

Calculation display value

*3
*6

DINT

R

42 to 63 Reserved for system

64

Group2 Entry count

DINT

R

12

65

Bank 0 HIGH setting

DINT

R/W

+005.0000

-099.999 to +999.999

66

Bank 0 LOW setting

DINT

R/W

+002.0000

-099.999 to +999.999

67

Bank 0 preset value

DINT

R/W

000.0000

-099.999 to +999.999

68

Bank 1 HIGH setting

DINT

R/W

+005.0000

-099.999 to +999.999

69

Bank 1 LOW setting

DINT

R/W

+002.0000

-099.999 to +999.999

70

Bank 1 preset value

DINT

R/W

000.0000

-099.999 to +999.999

71

Bank 2 HIGH setting

DINT

R/W

+005.0000

-099.999 to +999.999

72

Bank 2 LOW setting

DINT

R/W

+002.0000

-099.999 to +999.999

73

Bank 2 preset value

DINT

R/W

000.0000

-099.999 to +999.999

74

Bank 3 HIGH setting

DINT

R/W

+005.0000

-099.999 to +999.999

75

Bank 3 LOW setting

DINT

R/W

+002.0000

-099.999 to +999.999

76

Bank 3 preset value

DINT

R/W

000.0000

-099.999 to +999.999

77 to 95 Reserved for system

96

Group3 Entry Count

DINT

R

7

97

Key lock

DINT

R/W

0

0: Unlock
1: Full key lock