Reading an output from a sensor amplifier

Available outputs: High, Low, Go
This example shows how to read the High output from Slot 1 (ID01).

(1) The output from the sensor amplifier entered into Bit 0 of the input address 16 via

data I/O communication.

This example shows how to read the High output from the sensor amplifier ID01.

Entering an external input to a sensor amplifier

Available external inputs: PRESET, TIMING, RESET, error clear
This example shows how to enter the TIMING input from Slot 1 (ID01).

(1) The output address value to which an external input request was assigned is linked

via data I/O communication and the external input of the sensor amplifier is turned
on or off.

(2) You can check the input status of the sensor amplifier with the external input

response.

Reference

After the external input is executed, the button operation of the sensor
amplifiers is locked for about 10 seconds. "COM-Lock (comLoc)" is displayed
for about 2 seconds during switching to the locked state or when an attempt
is made to operate a locked button. When button operation is unlocked,
"COM-Unlock (comUnL)" is displayed for about 2 seconds. However, the
initialization screen appears when an initialization reset is executed. If an
external input is repeatedly executed when the initialization screen is being
displayed, the initialization screen is retained.

Output

High output of ID01

Sensor amplifier

Master

Sot 1

Bit 0 of the input address 16

1

0

ON

OFF

(1)

(2)

(1)

Master

External input request

External input response

Sensor amplifier

External input

TIMING input of ID01

1
0

ON

OFF

1

0

Slot 1

Bit 1 of the output address 1

Slot 1

Bit 1 of the input address 18