KEYENCE DL-PN1 User Manual
Page 17
15
- PROFINET Communication Unit DL-PN1 User's Manual (GT) -
98
Bank switching state
*7
DINT
R
0
0 to 3: Currently active bank
W
0
0: Switched to bank 0
1: Switched to bank 1
2: Switched to bank 2
3: Switched to bank 3
99
Timing status
*8
DINT
R
0
0: Timing input OFF, or in
process of measurement
using self-timing
1: Timing input ON, or not in
process of measurement
using self-timing
W
0
0: Change during measurement
1
: Change during non-measurement
100 to
102
Reserved for system
103
Bar display mode
DINT
R/W
0
0: Bar display mode
1: OK/NG display mode
104 to
127
Reserved for system
128
Group4 Entry count
DINT
R
26
129
Calculation mode and Setting
*9
DINT
R/W
0
0: OFF
1: Maximum value
2: Minimum value
3: Flatness
4: Average
5: Reference difference
6: Twist
7: Warpage
8: Thickness
130
Detection mode
DINT
R/W
0
0: Standard
1: NG hold
2: Peak hold
3: Bottom hold
4: Peak-to-Peak
131
Reserved for system
132
Response time
DINT
R/W
3
0: HSP (1.5 ms)
1: 5 ms
2: 10 ms
3: 100 ms
4: 500 ms
5: 1000 ms
6: 5000 ms
133
Timing type
DINT
R/W
0
0: External timing input
1: Rising self
2: Falling self
134
Self-timing level
DINT
R/W
+000.5000
-099.999 to +999.999
135
Self-timing delay type
DINT
R/W
0
0: Static hold
1: Delay timer
136
User-specified delay time
DINT
R/W
1000
0 to 9999
137
Static hold determination
DINT
R/W
0
0: Default
1: User
138
Static hold stable range
DINT
R/W
+000.010
000.000 to +999.999
139
Measurement direction
DINT
R/W
0
0: Normal
1: Reverse
140
Multiplier
DINT
R/W
001.0
000.1 to 100.0
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value