beautypg.com

KEYENCE DL-PN1 User Manual

Page 17

background image

15

- PROFINET Communication Unit DL-PN1 User's Manual (GT) -

98

Bank switching state

*7

DINT

R

0

0 to 3: Currently active bank

W

0

0: Switched to bank 0
1: Switched to bank 1
2: Switched to bank 2
3: Switched to bank 3

99

Timing status

*8

DINT

R

0

0: Timing input OFF, or in

process of measurement
using self-timing

1: Timing input ON, or not in

process of measurement
using self-timing

W

0

0: Change during measurement
1

: Change during non-measurement

100 to

102

Reserved for system

103

Bar display mode

DINT

R/W

0

0: Bar display mode
1: OK/NG display mode

104 to

127

Reserved for system

128

Group4 Entry count

DINT

R

26

129

Calculation mode and Setting

*9

DINT

R/W

0

0: OFF
1: Maximum value
2: Minimum value
3: Flatness
4: Average
5: Reference difference
6: Twist
7: Warpage
8: Thickness

130

Detection mode

DINT

R/W

0

0: Standard
1: NG hold
2: Peak hold
3: Bottom hold
4: Peak-to-Peak

131

Reserved for system

132

Response time

DINT

R/W

3

0: HSP (1.5 ms)
1: 5 ms
2: 10 ms
3: 100 ms
4: 500 ms
5: 1000 ms
6: 5000 ms

133

Timing type

DINT

R/W

0

0: External timing input
1: Rising self
2: Falling self

134

Self-timing level

DINT

R/W

+000.5000

-099.999 to +999.999

135

Self-timing delay type

DINT

R/W

0

0: Static hold
1: Delay timer

136

User-specified delay time

DINT

R/W

1000

0 to 9999

137

Static hold determination

DINT

R/W

0

0: Default
1: User

138

Static hold stable range

DINT

R/W

+000.010

000.000 to +999.999

139

Measurement direction

DINT

R/W

0

0: Normal
1: Reverse

140

Multiplier

DINT

R/W

001.0

000.1 to 100.0

Index

(DEC)

Function name

Description

Data

type

Attribute

Default

value

Value