Specifications
The specifications of the DL-PN1 are as follows:
Product name
PROFINET I/O Communication Unit
Model
DL-PN1
Suitable network
PROFINET I/O communication
Ethernet
Compliant standards
IEEE 802.3u (100BASE-TX)
Transmission rate
100 Mbps (100BASE-TX)
Transmission medium
STP cable or Category 5e or higher UTP cable (100BASE-TX)
Maximum cable length
100 m
PROFINET
Compatible functions
Data I/O communication
Record data communication
No. of connectable
PROFINET I/O controllers
1
Update Time
2 - 512 ms
GSDML version
V2.3
Conformance class
Conforms with Conformance Class A
Conformance test version
Conforms with V2.2.4
Suitable protocols
LLDP, DCP
Sensor connection
specifications
Connectable sensors
Sensor amplifiers with D-bus support
Number of connectable
sensor units
10 units max.
Indicator lamps
Link/activity indicator (LINK/ACT): Green LED
System failure indicator (SF): 2-color (orange/red) LED
Bus failure indicator (BF): Red LED
Sensor communication indicator (D-bus): 2-color (green/red) LED
Power voltage
20 to 30 V DC, including ripple (p-p)10%
supplied from the connected sensor amplifiers
Power consumption
1500 mW or less (at 30 V 50 mA max.)
Environmental
resistance
Operating ambient air
temperature
-20 to +55°C (no freezing)
Operating ambient air
humidity
35 to 85% RH (no condensation)
Vibration resistance
10 to 55 Hz compound amplitude 1.5 mm, 2 hours each in X, Y, Z
directions
Pollution degree
2
Materials
Main unit: Polycarbonate
Weight
Approx. 70 g