The indicator LEDs on the DL-PN1 can be used to determine the causes of errors.
Link/activity indicator (LINK/ACT)
This indicator indicates whether the DL-PN1 is communicating correctly.
System Failure indicator (SF)
This indicator indicates whether the DL-PN1 is operating normally.
Link/activity indicator (Green)
System Failure indicator (Orange, Red)
Bus Failure indicator (Red)
Sensor communication indicator (Green, Red)
LED Status
Condition
Corrective Action
Green
Solid
The DL-PN1 is normally linked.
-
Flashing
The DL-PN1 is normally linked and is
now exchanging data.
-
Not lit
Power is not supplied to the DL-PN1.
The DL-PN1 is not linked.
• Check if the power supply is correctly connected.
• Check if the DL-PN1 is correctly connected to the
sensor amplifier.
• Check if the IP address is correct.
• Check if the power supply of the connected device
or Ethernet switch is correctly connected.
• Check if the cable is correctly connected.
LED Status
Condition
Corrective Action
Solid red
There may be a system error on the
DL-PN1 or a connected sensor.
• Check the D-bus LED status.
• Check if the number of connected sensor
amplifiers exceeds the maximum number of
connectable units.
• Check if the IP address is correct.
• Check if the slot number is correct.
• Check if the DL-PN1 is correctly connected to the
sensor amplifier.
• Check if there is an electrical noise source near the
DL-PN1.
Flashing orange
Flash LED was requested on the I/O
controller.
Flashes approximately 4 times per
second.
-
Not lit
The DL-PN1 is normally operating.
-