2 troubleshooting, Troubleshooting -3, Troubleshooting – KEYENCE DL-DN1 User Manual
Page 65

5-3
5
A
p
pe
nd
ix
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-MH) -
5-2
Troubleshooting
The indicator lamps on the main unit can be checked to determine the cause of error
and the corrective actions to take.
Module status indicator (MS)
This lamp indicates whether the DL-DN1 is operating properly.
Network status indicator (green)
Sensor communication indicator (green)
Module status indicator (green)
LED indications 
during normal operation
LED status
Condition
Corrective action
Green
Solid
Operating properly.
-
Flashing
On standby.
• Check that cables and termi-
nating resistors are con-
nected correctly.
• Check that the master unit is
operating correctly.
Red
Solid
The DL-DN1 may have 
failed.
Contact your nearest sales 
office.
Flashing
Data link configuration was 
changed while in operation.
Check the configuration of the 
data link between the DL-DN1 
and master unit, and then cycle 
power.
Green/
red
Flashing
The DL-DN1 is checking its 
operation in the power-on 
process.
After completing the check, the 
DL-DN1 automatically switches 
to the normal state.
Not lit
Power is not supplied to the 
DL-DN1.
Check that the DL-DN1 is cor-
rectly connected with the sensor 
amplifiers.