3-3 Explicit Messaging
3-28
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-MH) -
3
Co
mm
u
ni
c
a
ting
w
ith t
he FD
-M
H
s
er
ie
s
Nx10+4
6C
Integrated flow
quantity unit
R/W
-
2
6D to
70
System reserved
71
N.O/N.C
R/W
-
0
Bit 0: Output 1 (1: N.C.)
Bit 1: Output 2 (1: N.C.)
Bit 2: Output 3 (1: N.C.)
72
Display mode
R/W
FD-MH10A
0
0: Std
1: rESo
FD-MH50A
1
FD-MH100A
1
FD-MH500A
0
73
Hysteresis
*7
R/W
FD-MH10A
0.10 0.00 to 9.99 *3
FD-MH50A
00.5 00.0 to 49.9 *3
FD-MH100A
01.0 00.0 to 99.9 *3
FD-MH500A 005.0 000.0 to 499.9 *3
74
Bank switching function
R/W
-
1
0: OFF
1: ON
75
System reserved
76
Flow rate zero function
R/W
-
0
0: OFF
1: ON
77
System reserved
78
Frequency mode
R/W
-
0
0: Standard
1: Frequency mode
79 to
7A
System reserved
7B
Power save mode
R/W
-
0
0: Do not use
1: Use
7C to
80
System reserved
81
Flow indicator color
R/W
-
1
0: Red for ON, green for OFF
1: Green for ON, red for OFF
82 to
83
System reserved
Nx10+5
64
Group-5 entry count
R
-
2
65 to
83
System reserved
Nx10+6
64
Group-6 entry count
R
-
11
65
Product Code
R
-
-
FD-MA*A: Main unit: 4004
FD-MA*A: Expansion unit: 4005
FD-MA*: Main unit: 4002
FD-MA*: Expansion unit: 4003
66
Revision
R
-
-
0101H to FFFFH
InstID
(DEC)
AttrID
(HEX)
Name
Description Attribute
Sensor
head
Default
value
Parameter range
Data
FD-
MH10A
FD-
MH50A
FD-
MH100A
FD-
MH500A
0
0.01
Cannot be set.
Cannot be set Cannot be set.
1
0.1
0.1
0.1
Cannot be set.
2
1
1
1
1
3
10
10
10
10
4
100
100
100
100
5
Cannot be set.
1000
1000
1000
6
Cannot be set Cannot be set Cannot be set.
10000