2 i/o communication, Co mm u ni c a ting w ith t he fd -m h s er ie s – KEYENCE DL-DN1 User Manual
Page 34

3-2 I/O Communication
3-6
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (FD-MH) -
3
Co
mm
u
ni
c
a
ting
w
ith t
he FD
-M
H
s
er
ie
s
"3-output + current value" mode
5-output mode
"5-output + current value" mode
3-output + monitor
No extended mode
Yes
-
-
3-input
-
Yes
Yes
Setting value rewrite
-
-
Yes
Area
IN
OUT
IN
OUT
IN
OUT
Number of sensor amplifi ers
1
14
0
20
6
28
24
2
18
24
32
3
22
28
36
4
26
32
40
5
30
36
44
6
34
40
48
7
38
44
52
8
42
48
56
9
46
52
60
10
50
56
64
(bytes)
5-output
No extended mode
Yes
-
-
5-input
-
Yes
Yes
Setting value rewrite
-
-
Yes
Area
IN
OUT
IN
OUT
IN
OUT
Number of sensor amplifi ers
1-10
12
0
22
10
34
40
(bytes)
5-output + current value
No extended mode
Yes
-
-
5-input
-
Yes
Yes
Setting value rewrite
-
-
Yes
Area
IN
OUT
IN
OUT
IN
OUT
Number of sensor amplifi ers
1
18
0
28
10
40
40
2
22
32
44
3
26
36
48
4
30
40
52
5
34
44
56
6
38
48
60
7
42
52
64
8
46
56
68
9
50
60
72
10
54
64
76
(bytes)