Nx10+1

69

Instantaneous flow rate
(current value)

*3

R

FD-MH10A

-

00.00 to 99.99

FD-MH50A

FD-MH100A

000.0 to 999.9

FD-MH500A

0000.0 to 9999.9

6A

Integrated flow quantity

*4

R

FD-MH10A

-

0000000.00 to 4294967.29

FD-MH50A

FD-MH100A

00000000.0 to 42949672.9

FD-MH500A

000000000 to 429496729

6B

Instantaneous flow rate
(peak hold value)

*3

R

FD-MH10A

-

00.00 to 99.99

FD-MH50A

FD-MH100A

000.0 to 999.9

FD-MH500A

0000.0 to 9999.9

6C

Instantaneous flow rate
(bottom hold value)

*3

R

FD-MH10A

-

00.00 to 99.99

FD-MH50A

FD-MH100A

000.0 to 999.9

FD-MH500A

0000.0 to 9999.9

6D to

6E

System reserved

6F

Bank switching state

R

-

-

0: Bank A
1: Bank B

70

System reserved

71

Current temperature

*5

R

-

-

000.0 to 999.9

72

Temperature
(peak hold value)

*5

R

-

-

000.0 to 999.9

73

Temperature
(bottom hold value)

*5

R

-

-

000.0 to 999.9

74 to

77

System reserved

78

External Input Status

R

-

-

0: OFF
1: ON

79

System reserved

7A

Temperature sensor
connection

*6

R

-

-

0: Not connected
1: Connected

7B to

83

System reserved

Nx10+2

64

Group-2 entry count

R

-

8

65

Instantaneous flow rate
setting 1(P1)

*7

R/W

FD-MH10A 03.00 00.00 to 30.00

FD-MH50A 015.0 000.0 to 100.0

FD-MH100A 030.0 000.0 to 200.0

FD-MH500A 100.0 000.0 to 999.9

66

Instantaneous flow rate
setting 2(P2)

*7

R/W

FD-MH10A

10.0 00.00 to 30.00

FD-MH50A 050.0 000.0 to 100.0

FD-MH100A 100.0 000.0 to 200.0

FD-MH500A 200.0 000.0 to 999.9

67

Temperature higher limit
setting

*8

R/W

-

080.0

100.0: Disable upper limit detection
000.1 to 099.9 upper limit value

68

Temperature lower limit
setting

*9

R/W

-

005.0

000.0: Disable lower limit detection
000.1 to 099.9 lower limit value

69

Integrated flow quantity
setting 1

R/W

-

0150 0000 to 9999

6A

Integrated flow quantity
setting 2

R/W

-

9999 0000 to 9999

InstID
(DEC)

AttrID
(HEX)

Name

Description Attribute

Sensor

head

Default

value

Parameter range