Setpoints -10, About setpoints -10 dead band limits -10 – Hardy HI 200DNWM DeviceNet Weigh Module User Manual
Page 44

HI 200DNWM MANUAL
5-10
parameter. During the execution of the com-
mand, the output polled data reflects the
input polled data.
Setpoints
About Set-
Points
The set point value is the target weight or
level in either net or gross weight units
Dead Band
Limits
The dead band value can be set as a High or
Low value. It is used to deactivate the set
point.
For example:
If a set point value was 1000 pounds and the
dead band was set to 5 pounds, the relay
would close at a 1000 pounds but not open
until the weight dropped to 995 pounds. This
is used if a set point is a high trip limit. A
High dead band would be used for a low trip
limit. Examples are show for Low and High
Trip Limits in Fig. 5-2.