Hardy HI 200DNWM DeviceNet Weigh Module User Manual
Page 14

HI 200 DNWM MANUAL
2-2
Temperature Coef-
ficient
Less than 0.0005% per degree C for zero and
span.
Temperature
Range
-10 degrees C to +50 degrees C
Temperature Stor-
age Range
-20 degrees to +85 degrees C
Physical Dimen-
sions
3.80” W x 8.5” L x 1.0” H (96.52 mm W x
215.9 mm L x 25.4 mm H)
Mounting Config
•
DIN - Rail
•
Enclosure Mounting, pc board mounted
to enclosure backplate.
Approvals
ODVA Conformance Tested
Display
None
DeviceNet
Type: Vendor Specific
I/O Slave Messaging: Polling
Profile: Refer to EDS
Baud Rates: 125K, 250K, 500K
Inputs
4 bytes polled in
Outputs
4 bytes polled out
NOTE:
The Metric Poll parameter specifies the default for-
mat of the 4 bytes of output data from the weight
scale. A zero value specifies that the default format is
a 32 byte integer value containing net weight in
pounds, with 3 decimal places. A one value specifies
that the default format is a 32 byte integer value con-
taining net weight in kilograms, with 3 decimal
places.