background image

Cub Cadet Commercial M60 Tank - 2002 and prior years

31

5.

Make certain both hydrostatic pump release rods
are in the operate position. See Figure 2.

6.

Start the unit and release the parking brake. See
Figure 3.

Figure 2

Pump Release Rod

Figure 3

7.

With the rear of the unit off the ground, bring the
lap bars to the operate position. See Figure 4.

8.

Identify the rear axle that is creeping.

NOTE: The hydraulic fluid must be brought to
operating temperature (130 degrees F.) to cor-
rectly test for creep. The engine must be run at
full RPM.

9.

Lower the throttle to idle and shut the unit off.

10.

Locate the adjustable hydrostatic connecting rod
that pivots the neutral return plate on the hydro-
static transmission assembly that is creeping.
See Figure 5.

Figure 4

Figure 5

Connecting Rods

Neutral Return Plate

Hex

Jam

Nuts