35.

Install both hydraulic elbow fittings to the correct
position using an 11/16” wrench. See Figure 16.

NOTE: Make certain the O-rings do not get dam-
aged during installation.

36.

Set the large O-ring onto the hydrostatic pump
assembly.

37.

Set the 14T spur gear on the output shaft of the
hydrostatic pump assembly.

38.

Loctite the hydrostatic mounting studs.

NOTE: Use Loctite 271

39.

Place the transmission assembly over the hydro-
static assembly and secure it in position with four
hex flange lock nuts using a 1/2" socket and a
1/2" wrench. See Figure 17.

Figure 16

Hydraulic Elbow Fittings

O Ring

14T Spur Gear

Loctite

Mounting

Studs

Figure 17

Transmission

Hydrostat

Hex Flange

Lock Nuts

40.

Place the hydrostatic pulley and fan onto the
input shaft.

41.

Secure the hydrostatic pulley and fan to the input
shaft with a flat washer and hex insert lock nut
using a 3/4" socket. See Figure 18.

Figure 18

Pulley

Fan

Input Shaft

Flat Washer and

Hex Insert Lock Nut