Chapter 2 - set-up and installation, Installing the 9145, Chapter 2 set-up and installation – CANOGA PERKINS 9145 Network Interface Device User Manual
Page 11
Chapter 2
Set-up and Installation
This section describes how to set up and install the 9145 and its interface modules.
Before setting up the 9145, make sure a 9 pin RS-232 cable is available (required to
connect the 9145’s Management Port to a VT100 type terminal or PC for setup and
configuration).
Installing the 9145
The 9145 is tested and inspected before shipment from the factory. If there is obvious
damage to the shipping container, contact the carrier immediately.
Caution: Follow electrostatic discharge (ESD) safety precautions when handling
Canoga Perkins products, as with all electronic devices with static
sensitive components.
1. Unpack the 9145. Keep the shipping container until the unit is installed and fully
operational. In the unlikely event that the unit is defective, contact Canoga Perkins
Customer Service for a Return Authorization Number (RMA) and instructions for return
shipment. Additional Warranty and Product Return information is in Appendix A.
2. The 9145 can be rack mounted, wall mounted, or placed on a shelf or any other flat
surface.
a. Rack Mounting: To rack mount the 9145, attach Rack Mount Kit 1802-2008 for
19” racks, or Rack Mount Kit 1802-2009 for 23” racks. The Rack Mount Kits
includes mounting brackets and screws to attached the brackets to the 9145..
The brackets attach to the three threaded holes on the side of the 9145 toward
the front. Be sure to place the Lock Washer between the Screw Head and
Bracket as shown figure 5.
Figure 2 – 9145 with 19” Rack Mount Brackets
Figure 3 – 19” Rack Mount Kit
Figure 4 – 23” Rack Mount Kit