beautypg.com

Waterworks Formwork Floor Mounted Exposed Tub Filler with Handshower and Metal Jostick Handle User Manual

Installation guidelines

background image


PRODUCT SUPPORT 800.927.2120 8am - 6pm EST

FORMWORK
Floor Mounted Exposed Tub Filler

Installation Guidelines

Page 1 of 4

Rev - 01


8.18.2014

These guidelines have been prepared for the professional contractor to aid in the installation of:
FORMWORK FLOOR MOUNTED EXPOSED TUB FILLER WITH METAL JOYSTICK HANDLE [STYLE No. FMXT70,
FM70XT (UK)] & FORMWORK FLOOR MOUNTED EXPOSED TUB FILLER WITH HANDSHOWER AND METAL
JOYSTICK HANDLE [STYLE No. FMXT90, FM90XT (UK)]
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

STYLE No. FMXT70†

STYLE No. FMXT90†

with Metal Joystick Handle

with Handshower and

Metal Joystick Handle

SPECIFICATIONS:

Anti-scald Protection: No
Inlet Connection Size & Type: 1/2" Female NPT†
Fittings Hole Diameter: Ø3-7/8" (98mm)
Hot Limit Safety Stop: No
Integrated Diverter: No
Spout Reach: 8-7/8" (225mm)
Water Pressure Minimum: 20 psi (1.4 Bar)
Water Pressure Maximum: 80 psi (5.5 Bar)
Water Pressure Recommended: 45 psi (3 Bar)
Unrestricted Flow Rate: 8 - 10 gpm (30 – 38 L)

† UK Style No.

FM70XT & FM90XT are supplied with 2

BSP adapters, assembly required.

IMPORTANT:

To ensure this product is installed properly, you must

read and follow these guidelines. The owner/user of
this product must keep this information for future
reference.

This product must be on-site prior to rough-in. This

allows the installer to visualize the installation and
verify the center spread.

This product must be installed by a professional

licensed contractor.

Check tub measurements to assure the spout projects

far enough into the tub.

Install accessible hot and cold service stop valves to

facilitate servicing


Be sure your installation conforms to all federal, state,

and local codes.

Anti-scald protection is the responsibility of the

installer and according to applicable codes.

In the State of Massachusetts, all installations must

comply with the rules and regulations set forth within
248 CMR.

Refer to the specification and assembly drawings

attached. Product is sold partially assembled but
shown fully disassembled for illustrative and service
purposes only.

Inspect the product to ensure you have all the parts

required for proper installation.

Use only a strap wrench or protected/smooth-jaw

wrench on any finished surface.

Run 1/2" supply lines for maximum flow.


DO NOT use putty. Putty contains oil and can cause

permanent discoloration on certain materials such as
marble, granite and any porous surface.

ROUGH-IN:

The MOUNTING PLATE is 2-1/2" in height and should

be a minimum of 3/4" from the surface of the finished
floor as shown in Figure - 01.

FIGURE – 01


BLOCKING

SUB-FLOOR

FINISHED

FLOOR

MOUNTING

PLATE

BLOCKING

SUB-FLOOR

FINISHED

FLOOR

MOUNTING

PLATE

2-1/2"

3/4"

MIN

Ш3-7/8"

7/8"

This manual is related to the following products: