These guidelines have been prepared for the professional contractor to aid in the installation of:
OPUS CONCEALED DECK MOUNTED TUB FILLER WITH CROSS
HANDLES (OPTU91-K)
All dimensions are based on original specifications and are subject to change and variation.
Please consult your Design Associate for current specifications.
Installation Guidelines
Figure 1
1
Hand Shower
Escutcheon Assembly
Plastic Spacer
Locking Nut
Hose End, Threaded
Rubber Gasket
Metal Washer
Rubber Hose Gasket
Figure 2
Figure 3
Spout
Knob
Diverter
NOTES
➢ Use only a protected, smooth-jawed, or strap wrench
on any finished surface.
➢ For proper installation, the deck surface should be
installed prior to mounting the mixer.
➢ It is recommended that an access panel be provided for
future servicing.
➢ Check the specifications (left) for drilling hole sizes.
➢ Run ¾" supply lines for maximum water flow.
➢ Accessible shut-off valves, which will facilitate servicing,
are recommended for the hot and cold feed lines.
➢ DO NOT use putty on deck fittings. Upper gaskets are
provided.
INSTALLATION
➢ To remove the handle trim from the handle trim
connector, unscrew the cover and pull off the handle
and cover together.Then unscrew and lift off the handle
trim connector. Leave locking nut, gaskets,and plastic
spacer in place on the valve body (see fig. 1).
➢ Insert the valve body through the mounting hole using
the plastic spacer (used for deck surfaces less than 1½"
thick).Then screw the handle trim connector onto the
valve body until fully seated. Next, tighten the bottom
locking nut to secure the valve to the deck. Repeat for
the other valve assembly.
➢ Re-attach the handle trims to the handle trim
connector.
➢ Remove the locking nut, gasket and tee assembly from
the spout shank and insert spout through the mounting
hole. Please note that the diverter lift knob must be
unthreaded before removing the tee assembly. (see fig.
2).
➢ Re-attach the locking nut and gasket to spout shank and
tighten until spout is fully secured.Then re-attach the
tee assembly and diverter lift knob.
➢ Install the flexible supply hoses between the valve
bodies and the tee assembly.
OPTU91-K