LUDLOW

Pressure Balance Control Valve Trim

INSTALLATION GUIDELINES

Page 3 of 3

10.30.2013

These guidelines have been prepared for the professional contractor to aid in the installation of:
LUDLOW PRESSURE BALANCE TRIM WITH LEVER HANDLE (STYLE# LDPB10)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

¾ See Figure 5. for Step 8 - 11.

8. Slide the NOSE CONE CAP over the VALVE STEM

and into NOSE CONE.

9. Remove SET SCREWS from HANDLE ASSEMBLY.

10. Insert the HANDLE ASSEMBLY onto the valve stem

until it is fully seated, making sure it is in the correct
orientation.

11. While holding the HANDLE ASSEMBLY (i), slide the

NOSE CONE CAP back out to reveal the set screw
holes. Tighten both SET SCREWS (ii) and return
NOSE CONE CAP to complete this installation (iii)
For details refer to Figure 5a.

Figure 5

VALVE STEM

NOSE CONE CAP

SET SCREWS

NOSE CONE

HANDLE ASSEMBLY

Figure 5a

TIGHTEN

SET

SCREWS

NOSE
CONE CAP

i

ii

iii

¾ NOTE: The screws on the trim plate are aesthetic

and do not serve any mechanical purposes and
should not be removed.

¾ Note: There is a notch on the bottom of the TRIM

PLATE for easy removal.

¾ If further assistance is required, please contact

Product Support at 1-800-927-2120 (9am-6pm EST).