Installation guidelines – Waterworks Easton Classic Three Cross Handle Exposed Thermostatic System with Shower Rose and Handshower User Manual
Page 3
PRODUCT SUPPORT 800.927.2120 8am - 6pm EST
EASTON CLASSIC
Exposed Thermostatic System with 8" Shower Rose
Installation Guidelines
Page 3 of 3
Rev - 01
11.11.2013
These guidelines have been prepared for the professional contractor to aid in the installation of:
EASTON CLASSIC EXPOSED THERMOSTATIC SYSTEM WITH 8" SHOWER ROSE (STYLE No. EAXS42) &
EASTON CLASSIC EXPOSED THERMOSTATIC SYSTEM WITH 8" SHOWER ROSE AND HANDSHOWER
(STYLE No. EAXS52)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
11. Slowly rotate the valve stem clockwise to attain
full cold then rotate it counterclockwise to attain
full hot. Verify that a full range of temperatures
exists.
12. With water running, rotate the valve stem to
adjust the temperature to the maximum desired
bathing temperature, verified with a
thermometer. Turn the water off and make sure
not to change this temperature setting.
13. Place the limit stop back, using the washer, onto
the valve stem making sure the limit stop pin
makes contact with the limit stop on valve face
plate then tighten the set screws.
INSPECT THE INSTALLATION:
14. Turn the limit stop clockwise then turn the water
on and confirm the limit stop is functioning
properly by turning it counterclockwise at which
point it should stop.
15. Verify the temperature to be the maximum
temperature set in Step 12 then turn the water
off. If it is not the correct temperature, repeat
the calibration procedures.
16. To get a hotter temperature, press and hold the
limit stop button then rotate the limit stop until
it stops. It is NOT recommended to exceed the
safety limit stop of 100 degrees.
FINISH THE INSTALLATION:
¾ If a handshower will be installed, continue with
steps 17 - 18; If not, continue with step 19:
17. Attach the handshower cradle onto the shower
arm at the desired height using the screws and
nuts provided.
WASHER
PIN
WASHER
PIN
18. Connect the conical end of the handshower hose
to the handshower and the hex end to the
bottom of the valve body. Place the handshower
on the cradle. NOTE: There is a 2.5gpm flow
regulating check valve in the handshower.
19. Attach the shower head to the shower arm using
the rubber washer provided. NOTE: There is a
2.5gpm flow regulator in the pivot ball.
20. If desired, a bead of caulk or a clear silicone may
be applied where the escutcheons contact the
finished wall. DO NOT use putty.*
21. Turn on the volume control valve(s) and carefully
inspect all connections for leaks and check for
proper operation.
¾ If further assistance is required, please contact
Product Support at 1-800-927-2120 Ext 2
Monday through Friday, 8am - 6pm EST.
* Putty contains oil and can cause permanent
discoloration on certain materials such as marble,
granite and any porous surface.
NUT
SHOWER ARM
RETAINING
COLLAR
CRADLE
SCREW
NUT
SHOWER ARM
RETAINING
COLLAR
CRADLE
SCREW
FLOW REGULATOR
SHOWER HEAD
RUBBER WASHER
SHOWER ARM
FLOW REGULATOR
SHOWER HEAD
RUBBER WASHER
SHOWER ARM