Installation guidelines – Waterworks Easton Classic Three Cross Handle Exposed Thermostatic System with Shower Rose and Handshower User Manual
Page 2
PRODUCT SUPPORT 800.927.2120 8am - 6pm EST
EASTON CLASSIC
Exposed Thermostatic System with 8" Shower Rose
Installation Guidelines
Page 2 of 3
Rev - 01
11.11.2013
These guidelines have been prepared for the professional contractor to aid in the installation of:
EASTON CLASSIC EXPOSED THERMOSTATIC SYSTEM WITH 8" SHOWER ROSE (STYLE No. EAXS42) &
EASTON CLASSIC EXPOSED THERMOSTATIC SYSTEM WITH 8" SHOWER ROSE AND HANDSHOWER
(STYLE No. EAXS52)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
5. Turn on the water supply to flush out any debris
in the supply lines then turn them off.
6. Slide the escutcheons onto the nipples, making
sure to use the gasket provided. Hold the valve
up to the nipples and thread the union nuts onto
the nipples. Make sure to use the rubber washers
to create a proper seal and securely tighten.
7. Install the shower arm bracket using the
hardware provided. The bracket arm can be cut
to adjust the length. Make sure the set screw
creates a secure hold on the bracket arm.
8. Attached the shower arm to the valve body
using the rubber washer provided. Securely
tighten the union nut on the end of the shower
arm then secure the shower arm to the bracket
using the nuts and screw provided.
RUBBER
WASHER
UNION NUT
RUBBER
WASHER
UNION NUT
BRACKET
ARM
SET SCREW
MOUNTING
PLATE
ANCHOR
HEX KEY
SCREW
SET SCREW
ESCUTCHEON
BRACKET ARM
CAN BE CUT
SCREW
RETAINING
COLLAR
NUT
SHOWER
ARM
BRACKET
ARM
SET SCREW
MOUNTING
PLATE
ANCHOR
HEX KEY
SCREW
SET SCREW
ESCUTCHEON
BRACKET ARM
CAN BE CUT
SCREW
RETAINING
COLLAR
NUT
SHOWER
ARM
CALIBRATE THE TEMPERATURE:
¾ The risk of scalding exists until the installer has
properly calibrated the temperature setting.
9. Unthread the handle from the limit stop then
loosen the set screws to remove the limit stop
and expose the valve stem.
10. Turn on the water supply and integrated volume
control valve by rotating the handle
counterclockwise.
RUBBER WASHER
UNION NUT
SCREW
RETAINING
COLLAR
NUT
RUBBER WASHER
UNION NUT
SCREW
RETAINING
COLLAR
NUT
VALVE STEM
WASHER
VOLUME CONTROL
HANDLE
SET SCREW
LIMIT STOP
HANDLE
VALVE STEM
WASHER
VOLUME CONTROL
HANDLE
SET SCREW
LIMIT STOP
HANDLE