These guidelines have been prepared for the professional contractor to aid in the installation of:

PRESSURE BALANCE VALVE TRIM WITH DIVERTER

(BNSV88-K & GUSV86R) (WWSV86-K & GUSV86R) (WWSV87-K & GUSV86R)

(WWSV84-K & GUSV86R) (WWSV85-K & GUSV86R)

All dimensions are based on original specifications and are subject to change and variation.

Please consult your Design Associate for current specifications.

Installation Guidelines

1

Refer to the specification and assembly drawings attached.

Valves are sold partially assembled but shown fully
disassembled for illustrative and service purposes only.

Before soldering any connections, remove cartridge to

prevent damage to seals.

This valve should be on-site prior to rough in and allows the

installer to visualize the installation.

Inspect this product to assure you have all parts required for

proper installation.

Check incoming water pressure; ideal operating pressure is

40-50 psi.The minimum is 25 psi. and the maximum is 80 psi.

Use only a strap wrench or protected/smooth-jaw wrench on

any finished surface.

ROUGH IN:
1. Make sure the valve body is positioned according to valve

markings so the inlets are situated with hot piped on the left
and cold piped on the right.

2. Remove and discard the wall mounting flange(T-177) located

beneath the tile shield.The dome cover(T-19) included will
not be used during the installation.

3. REQUIRED: Valve body rough-in depth is 2 3/8" +/- ½" from

the centerline of the supplies/inlets to the face of the finished
wall. Install so the back side of the plaster shield contacts the
finished wall as indicated on the shield.

4. Run 1/2" copper supply lines with a 5 ½" center spread to

the proper height of the valve inlets and be sure to secure all
piping and fittings.

5. Turn on the hot and cold supplies then check for leaks.

VALVE OPERATION:
6. When the finished wall is complete, turn on the hot and cold

supplies and pull off the tile shield(T-176) and discard. Both
supplies must be on or the valve will not operate.

7. The larger of the 2 handles is for controlling temperature

only, not volume. The smaller handle is used to divert the
water flow to another fitting. Install the large handle so it
rests at 6 o-clock in the OFF position then turn the handle
counter clockwise through the cold position then warm and
stopping at the hot position. If additional rotational friction is
required to maintain the handle position, tighten the packing
nut(T-17).

BNSV88-K(Beacon trim) & GUSV86R(rough)

2

5

/

8

"

6

1

/

2

"

1

"

3

/

16

"

1

/

4

"

5

/

8

"

1

/

2

"

shower

discharge

inlet

tub

discharge

3

7

/

16

"

1

/

4

"

1

/

2

"

2

3

/

8

1

/

2

"

5

1

/

2

"

1

/

2

" copper supply lines

2

5

/

8

"

6

1

/

2

"

1

/

4

"

1

/

4

"

5

/

8

"

1

/

2

"

shower

discharge

inlet

tub

discharge

5

5

/

8

"

1

/

4

"

1

/

2

"

2

3

/

8

1

/

2

"

5

1

/

2

"

5

/

8

"

1

/

2

" copper supply lines

2

5

/

8

"

6

1

/

2

"

1

/

4

"

1

/

4

"

5

/

8

"

1

/

2

"

shower

discharge

inlet

tub

discharge

5

5

/

8

"

1

/

2

"

2

3

/

8

1

/

2

"

5

1

/

2

"

5

/

8

"

1

/

4

"

1

/

2

" copper supply lines

WWSV86-K(Round trim with metal lever handle) & GUSV86R(rough)
WWSV87-K(Round trim with porcelain handle) & GUSV86R(rough)

WWSV84-K(Square trim with metal lever handle) & GUSV86R(rough)
WWSV85-K(Square trim with porcelain handle) & GUSV86R(rough)

IMPORTANT

To ensure this product is installed properly, you must read

and follow these guidelines.

The owner/user of the valve must keep this information for

future reference.

The risk of scalding exists until the installer has properly set

the temperature high limit stop.

This product must be installed by a professional contractor

and conform to all applicable codes