beautypg.com

Installation guidelines – Waterworks R.W. Atlas Thermostatic Control Valve Trim with Metal Lever Handle User Manual

Page 3

background image


PRODUCT SUPPORT 800.927.2120 8am - 6pm EST

RW ATLAS

Thermostatic Control Valve Trim

INSTALLATION GUIDELINES

Page 3 of 3


8.9.2012

These guidelines have been prepared for the professional contractor to aid in the installation of:
RW ATLAS THERMOSTATIC CONTROL VALVE TRIM WITH METAL WHEEL HANDLE (STYLE#
RWTH01) & METAL LEVER HANDLE (STYLE # RWTH10)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
SEE SERVICE PART DOCUMENT FOR PART ORDERING, AVAILABLE ON WATERWORKS.COM

TEMPERATURE CALIBRATION:

¾ The risk of scalding exists until the installer has

properly calibrated the temperature setting.

¾ See Figure - 04 for steps 11 - 15.

11. Turn on the water supply and a wall valve to run

water through the valve and insert a bladed screw
driver into the square tube.

12. Slowly rotate the square tube clockwise to attain full

cold, then rotate it counter-clockwise to attain full
hot. Verify a full range of temperature exists. Note: It
is approximately 2 complete rotations from full cold
to full hot.

13. With water running, rotate the square tube to adjust

the temperature to the maximum desired bathing
temperature, verified with a thermometer. Turn the
water off and make sure not to change this
temperature setting.

14. Unthread the handle assembly from the limit stop

assembly and loosen the 4 set screws on the limit
stop.

15. Insert the limit stop assembly onto the trim nut

making sure the limit stop pin (shown removed)
makes contact with the limit stop on the trim plate,
then tighten the 4 set screws.

Figure - 04

HANDLE ASSEMBLY

LIMIT STOP

ASSEMBLY

LIMIT STOP PIN
[SHOWN REMOVED]

INSPECT THE INSTALLATION:

16. Turn the limit stop clockwise then turn the water on

and confirm the limit stop is functioning properly by
turning it counter-clockwise at which point it should
stop.

17. Verify the temperature to be the maximum

temperature set in Step 13. If it is not the correct
temperature, repeat the calibration procedures in
Steps 11-15.

18. To get a hotter temperature, press and hold the limit

stop button, then rotate the limit stop until it stops.
It is NOT recommended to exceed a safety limit stop
of 110 degrees.

19. Re-attach the handle assembly to the limit stop.

¾ If further assistance is required, please contact

Product Support at 1-800-927-2120 (8am-6pm EST).

¾ See service part document for parts ordering,

available on WATERWORKS.COM.


This manual is related to the following products: