Waterworks Henry Volume Control Valve Trim User Manual
Installation guidelines
PRODUCT SUPPORT 800.927.2120 8am - 6pm EST
HENRY
Volume Control Valve Trim
INSTALLATION GUIDELINES
Page 1 of 2
11.2.2012
These guidelines have been prepared for the professional contractor to aid in the installation of:
HENRY VOLUME CONTROL VALVE TRIM WITH METAL CROSS HANDLE (STYLE# HNVC40) &
METAL LEVER HANDLE (STYLE # HNVC50)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.
SEE SERVICE PART DOCUMENT FOR PART ORDERING, AVAILABLE ON WATERWORKS.COM
Metal Cross Handle
Style No. HNVC40
Code No. HNSV40
Metal Lever Handle
Style No. HNVC50
Code No. HNSV50
SPECIFICATIONS:
Fitting Hole Diameter: 1-3/8"
Volume Control Valve Rough-In Depth:
GUVC16 or GUVC17: 2-3/8" MIN - 3-3/8" MAX
2-Way or 3-Way Diverter with Shutoff Valve Rough-In
Depth (For Thermostatic Systems):
GUDV14 or GUDV66: 2-1/2" MIN - 4-1/8" MAX
2-Way or 3-Way Diverter without Shutoff Valve Rough-
In Depth (For Pressure Balance Systems)::
GUDV23 or GUDV65: 3-1/8" MIN - 3-5/8" MAX
REQUIRED PLUMBING DETAILS:
Universal 3/4" Volume Control Valve (Clockwise Close)
STYLE No. GUVC16
CODE No. GUSV16R
Universal 3/4" Volume Control Valve (Counterclockwise
Close)
STYLE No. GUVC17
CODE No. GUSV17R
Universal 2-Way Diverter with Shutoff Valve
STYLE No. GUDV14
CODE No. GUSV14R
Universal 2-Way Diverter without Shutoff Valve
STYLE No. GUDV23
CODE No. GUSV23R
Universal 3-Way Diverter with Shutoff Valve
STYLE No. GUDV66
Universal 3-Way Diverter without Shutoff Valve
STYLE No. GUDV65
IMPORTANT:
¾
To ensure this product is installed properly, you
must read and follow these guidelines.
¾
The owner/user of this product must keep this
information for future reference.
¾
Be sure your installation conforms to federal state,
and local codes. In the State of Massachusetts, all
installations must comply with the rules and
regulations set forth within 248 CMR.
¾
This product must be installed by a professional
licensed contractor and must be onsite prior to
rough-in, this allows the installer to visualize the
installation.
¾
Wall valves control on/off/volume and must be
installed for each fitting that will have water flowing
to it. If using a wall valve with the Universal 3/4"
Thermostatic Valve (Style No. GUTH37R), refer to
the Installation Guidelines for the Thermostatic
Valve which contains related installation information.
¾
Inspect this product to ensure you have all the parts
required for proper installation.
¾
Use only a strap wrench or protected/smooth-jaw
wrench on any finished surface.
¾
DO NOT use putty on fittings.
CONTROL VALVE TRIM INSTALLATION WITH VOLUME
CONTROL VALVES GUVC16R/17R:
¾
See Figure - 01 for steps 1 & 2
1.
Pull the tile guard off the threaded sleeve from the
wall valve rough. Mark the threaded sleeve at the
finished wall. Unthread the sleeve and cut 1/2" in
front of the mark.
2. Mark the cartridge stem at the wall, then unthread
the cartridge from the valve body. Cut the cartridge
stems 1-3/8" in front of the mark.
3. After the cuts have been made, thread cartridge and