beautypg.com

Installation guidelines, Formwork – Waterworks Formwork Low Profile Three Hole Deck Mounted Lavatory Faucet with Metal Lever Handles User Manual

Page 3

background image


PRODUCT SUPPORT 800.927.2120 8am - 6pm EST

FORMWORK

Three Hole Deck Mounted Lavatory

Faucet

INSTALLATION GUIDELINES

Page 3 of 3


4.16.2014

These guidelines have been prepared for the professional contractor to aid in the installation of:
FORMWORK DECK MOUNTED LAVATORY FAUCET WITH METAL KNOB HANDLES (STYLE#
FMLS01) & METAL LEVER HANDLES (STYLE# FMLS10)
All dimensions are based on original specification and are subject to change and variation.
Please consult your Design Associate for current specifications.

12. Attach SUPPLY KIT [SOLD SEPARATELY] to inlet

on VALVE BODY, using the supply nut.

13. Repeat steps 4-12 to install the second handle

assembly.

DRAIN INSTALLATION:

¾ See Figure 5 for steps 14 - 17.

14. Remove the DRAIN FLANGE from LOWER DRAIN

BODY and remove the RUBBER GASKET.

15. Set the DRAIN FLANGE in the drain hole using putty

or a clear adhesive silicone depending on the
mounting surface material.*

16. Making sure the RUBBER GASKET and PLASTIC

WASHER are on the LOWER DRAIN BODY, thread
the LOWER DRAIN BODY onto the DRAIN FLANGE.
Securely tighten the LOWER DRAIN BODY, making
sure the RUBBER GASKET makes a full seal on the
underside of the lavatory. Putty or a clear adhesive
silicone may be used to ensure a water tight seal
between the RUBBER GASKET and lavatory.*

17. Attach the TAILPIECE to the LOWER DRAIN BODY

using the DRAIN NUT, making sure the RUBBER
WASHER is in between the LOWER DRAIN BODY
and TAILPIECE.

FIGURE - 05

INSPECT THE INSTALLATION:

18. Remove the flow restricting AERATOR using the

tool provided, then carefully open the hot and cold
valves to flush out any debris in the supply lines. See
Figure 1.

19. Inspect all connections for leaks.

DRAIN NUT

TAILPIECE

RUBBER WASHER

LOWER DRAIN BODY

PLASTIC WASHER

RUBBER GASKET

FOAM GASKET

DRAIN FLANGE

DRAIN STOPPER

DRAIN NUT

TAILPIECE

RUBBER WASHER

LOWER DRAIN BODY

PLASTIC WASHER

RUBBER GASKET

FOAM GASKET

DRAIN FLANGE

DRAIN STOPPER

20. Close the drain and fill the sink with water to make

sure the drain stopper and gasket operates and
seals properly.

21. Re-install the flow restricting aerator.

¾ If further assistance is required, please contact

Product Support at 1-800-927-2120 (8am-6pm EST).

¾ See service part document for parts ordering,

available on WATERWORKS.COM.

*

Putty contains oils and can cause permanent
discoloration on certain materials such as marble,
granite and any porous surface.