Pilz PSEN op4B-S-3-080 User Manual
Page 8

PSEN op4B Series
Operating Manual
4
Fig. 1
The resolution can be calculated using the following formula:
R = I + d
The table below specifies the values for the light curtains with regard to
the optical axis (I), the resolution (R) and the diameter of the optics (d).
Model
Optical
axis
mm
(I)
No. of
optics
(n)
Resolution
mm
(R)
Ø of optics
mm
(d)
Range
m
PSEN op4B-T-2-050
500 2 515 16 3
PSEN op4B-T-3-080
400 3 415 16
3
PSEN op4B-L-2-050
500 2 515 16
3
PSEN op4B-L-3-080
400 3 415 16
3
PSEN op4B-S-2-050
500 2 515 16
25
PSEN op4B-S-3-080
400 3 415 16
25