The resolution can be calculated using the following formula:

R = I + d


The table below specifies the values for the light curtains with regard to
the optical axis (I), the resolution (R) and the diameter of the optics (d).

Model

Optical

axis

mm

(I)

No. of
optics

(n)

Resolution

mm

(R)

Ø of optics

mm

(d)

Range

m

PSEN op4B-T-2-050

500 2 515 16 3

PSEN op4B-T-3-080

400 3 415 16

3

PSEN op4B-L-2-050

500 2 515 16

3

PSEN op4B-L-3-080

400 3 415 16

3

PSEN op4B-S-2-050

500 2 515 16

25

PSEN op4B-S-3-080

400 3 415 16

25