beautypg.com

Pilz PSEN op4B-S-3-080 User Manual

Page 25

background image

Operating Manual

PSEN op4B Series

21

4.2 Notes on wiring

To ensure the correct operation of the safety light curtain, please note
the following:

Safe electrical isolation must be ensured for the external 24 V

supply. Failure to do so could result in electric shock. The supply
voltage must conform to EN 60950, 03/97, section 2.3, EN 60742,
9/95 or EN 50178, 10/97.

Emitter and receiver must be connected using shielded cables

(accessories).
FIg. 14 shows how to connect the emitter and receiver properly.

Fig. 15

At the point where the cable enters the cabinet, connect the screen

to the earth bar, without making a break in the cable. Use metal
cable clamps which cover the screen over a wide surface area.

Under no circumstances should the connection cables come into

contact with or be laid in proximity to cables that generate strong
electromagnetic interference (e.g.: motor feeds, inverters etc.);
these could compromise the device’s ability to function.

Multicore cables may not be used to connect the outputs of more

than one safety light curtain.

This manual is related to the following products: