Pilz PSEN op4B-S-3-080 User Manual
Page 48
![background image](/manuals/647196/48/background.png)
PSEN op4B Series
Operating Manual
44
6.7.3
Installing the muting sensors on PSEN opB-T models
The integrated muting function in a T-shaped configuration enables the
muting sensors to be easily installed and is suitable for applications in
which the object is moved in two directions.
For correct operation set position 2 on the DIP switch to ON.
A1
B1
PSEN
A2
B2
Connecting the muting sensors:
Contact from A1
Contact from A2
Contact from B1
Contact from B2
24 Vcc
4-pin M12 connector
PSEN receiver
Pin 2
MUTING 1
Pin 4
MUTING 2
L
V=cons
D
D
d
•
The distance d1 between A1 and B1 or A2 and B2 is 16.5 cm.
•
The distance D between A1 and A2 or B1 and B2 is 34.5 cm.
•
Muting sensors A and B must be operated consecutively within
4 s.
This manual is related to the following products: