8 led control register (lctrl), Led control register (lctrl) – Kontron AM4024e User Manual
Page 47

D R A F T — F O R I N
T E R N A L U S E O N L Y
47
www.kontron.com
User Guide
AM4024(E)
Configured for Mode B, the User-Specific LEDs are dedicated to functions as follows:
ULED3:
Ethernet Link Status of AMC Gigabit Ethernet channel A, AMC port 0 (green)
ULED2:
Ethernet Link Status of AMC Gigabit Ethernet channel B, AMC port 1 (green)
ULED1:
SATA channels active (green)
ULED0:
--
Note:
If the ULED3 is lit red, the processor temperature is above 100° C.
If all ULEDs are blinking red, the processor temperature is above 125°C.
3.3.8 LED Control Register (LCTRL)
The LED Control Register enables the user to switch on and off the front panel User-Specific LEDs.
Note:
The LED Control Register can only be used if the User-Specific LEDs indicated in the LED
Configuration Register (Chapter 3.3.7) are configured in Mode A.
Table 32: LED Control Register (LCTRL)
ADDRESS
0x291
BIT
7
6
5
4
3
2
1
0
NAME
LCMD
LCOL
ACCESS
R/W
R/W
RESET
0000
0000
BITFIELD
DESCRIPTION
7..4
LCMD
User-Specific LED command:
0000 = Get ULED0
1000 = Set ULED0
0001 = Get ULED1
1001 = Set ULED1
0010 = Get ULED2
1010 = Set ULED2
0011 = Get ULED3
1011 = Set ULED3
0100 - 0111 = Reserved
1100 - 1111 = Reserved
3..0
LCOL
User-Specific LED color:
0000 = Off
0001 = Green
0010 = Red
0011 = Red+Green