Kontron AM4024e User Manual
Page 20
D R A F T — F O R I N
T E R N A L U S E O N L Y
20
www.kontron.com
User Guide
AM4024(E)
Gener
al
Power Consumption
See Chapter 4 for details.
Temperature Range
Operational: -5°C to +55°C
Standard (depending on processor version and air-
flow in the system)
Storage:
-40°C to +70°C
Without hard disk and without battery
Note:
When the RTC Backup Battery Module is installed, refer to the opera-
tional specifications of this module as this determines the storage tem-
perature of the AM4024(E). (See "RTC Backup Battery Module" below.)
Note:
When additional components are installed, refer to their operational
specifications as this will influence the operational and storage tem-
perature of the AM4024(E).
RTC Backup Battery Mod-
ule (on request)
Special battery mezzanine module with up to two batteries connected in parallel;
uses the J7 connector for interfacing with the AM4024(E)
Temperature ranges:
Operational: - 5°C to + 55°C
Storage:
-30°C to + 60°C
Climatic Humidity
93% RH at 40 °C, non-condensing (acc. to IEC 60068-2-78)
Dimensions
Dimensions of the AM4024(E) without retention screws on front panel:
Mid-size: 181.5 mm x 73.5 mm x 18.96 mm
Board Weight
280 grams
The above-mentioned board weight refers to the AM4024(E) without extension
modules such as the SATA Flash module or the RTC Backup Battery module.
Table 2: AM4024(E) Main Specifications (Continued)
FEATURES