Compressed air, Computer specifications, Drill and drill bit requirements – Dynojet 424x: Installation Guide User Manual
Page 18: Electrical requirements, Environmental requirements

Above Ground Model 424x/424xLC
2
Automotive Dynamometer Installation Guide
C H A P T E R 1
Dynamometer Specifications and Requirements
1-8
C
OMPRESSED
A
IR
The following requirements are needed for the air brake:
• Clean and dry air, between 100-140 psi
• shut off valve
• 1/4-inch NPT pipe thread connector (to attach air to the dyno), if air hose does not
have a 3/8-inch inside diameter
• have a 3/8-inch inside diameter
C
OMPUTER
S
PECIFICATIONS
You will need to provide a computer system to run the WinPEP software. A complete
list of system requirements can be found in your WinPEP 7 User Guide. This manual is
included with your dyno and is also available on your WinPEP 7 CD.
D
RILL
AND
D
RILL
B
IT
R
EQUIREMENTS
You will need to provide a drill and drill bit capable of drilling holes in concrete. Refer
to Appendix A for more information on installing Red Head Anchors.
• drill bit size: 1/2-inch
• minimum hole depth: 1 5/8-inch (41.2 mm)
E
LECTRICAL
R
EQUIREMENTS
The hydraulic pump/motor power source and eddy current braking power source
require user supplied grounded electrical outlets with over current and short circuit
protection. These must be accessible to the operator to be used as a disconnect.
E
NVIRONMENTAL
R
EQUIREMENTS
description
specifications
Power Requirements: 4WD electronics
100-240 VAC, 50/60 Hz
Power Requirements: dyno electronics
100-240 VAC, 50/60 Hz
Power Requirements: hydraulic motor
110 VAC, 60 Hz, 20A/240 VAC, 60 Hz, 10A
Power Requirements: computer
Per computer manufacturer specifications
Power Requirements: optional eddy
current brake
240v 30amp single phase circuit for each eddy current
brake
Refer to Appendix B for more information.
description
specifications
Temperature
operating min./max
10°C/50°C (50°F/122°F)
storage min./max
0°C/70°C (32°F/158°F)
Humidity
0 to 95% non condensing