Motor Specifications and Electrical Requirements (continued)
CAUTION: To avoid motor damage, this motor
should be blown out or vacuumed frequently to
prevent sawdust buildup which will interfere with
normal motor ventilation.
1
Frequent "blow ing" of fuses or tripping of circuit break
ers m ay result if;
a M otor is overloaded - O verloading can occur if you
feed too rapidly or if saw is m isaligned
b. M otor circuit is fused differently from recom m enda
tions - Alw ays follow instructions for the proper fuse/
breaker Do not use a fuse/breaker of greater
capacity w ithout consulting a qualified eiectrician
c Low voltage - Although the m otor is designed for
operation on the voltage and frequency specified on
m otor nam eplate, norm al loads will be handled
safely on voltage not m ore than 10% above or below
the nam eplate voltage- Heavy loads, how ever,
require that voltage at m otor term inals equals the
voltage specified on nam eplate.
2
M ost m otor troubles m ay be traced to loose or incor
rect
connections,
overloading,
reduced
input
voltage
(such as sm all size w ire in the supply circuit) or to
overly long supply circuit w ire. A lw ays check the con
nections,
the
load
and
the
supply
circuit
w henever
m otor fails to perform satisfactorily. C heck w ire sizes
and length w ith the W ire Size C hart below
Wire Sizes
NOTE;
M ake sure the proper extension cord is used and
is in good condition
The use of any extension cord will cause som e loss o1
pow er. To keep thfs to a m inim um and to prevent over
heating
and
m otor
burn-out,
use
the
table
show n
to
determ ine
the
m inim um
w ire
size
(A,W
G .)
extension
cord
U se
only
3-w ire
extension
cords
which
have
3-prong
grounding
type
plugs
and
3-prong
receptacles
w hich
accept the tool’s plug
Extension
Wire Sizes Required
Cord Length
for (A.W.G.)
0-25 Ft,
16
26-50 Ft
16