Motor Specifications and Electrical Requirements'
Power Supply and Motor Specifications
WARNING: To avoid electrical hazards, fire haz
ards or damage to the tool, use proper circuit pro
tection. Your tool is wired at the factory for
operation using the voltage shovim. Connect tool
to a power line with the appropriate voltage and a
IS-amp branch circuit. Use a 15-amp time delay
type fuse or circuit breaker. To avoid shock or fire,
it power cord is worn or cut, or damaged in any
way, have it replaced immediately.
The A -C m otor used in this tool is a reiay start, non-revsrs-
ibie type, having the follow ing specifications:
General Electrical Connections
DANGER: To avoid electrocution:
t. Use oniy identical replacement parts when ser
vicing, Servicing should be performed by a
qualified service technician.
2
.
Do not use in rain or where floor is wet.
This tool is intended for indoor residential use
only.__________________________________
110-120 Volt, 60 Hz. Tool Information
N O TE: The plug supplied on your tool m ay not fit ihto the
outlet you are planning to use Your local electrical code
m ay
require
slightly
different
pow er
cord
plug
connec
tions- If these differences exist refer to and m ake the
proper adjustm ents per your local code before your tool
is plugged in and turned on
In the event of a m alfunction or breakdow n, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock This tool is equipped
w ith an electric cord having an equipm ent-grounding con
ductor and a grounding plug, as shown. The plug m ust
be
plugged
into
a
m atching
outlet
that
is
properly
installed and grounded in accordance w ith all local codes
and ordinances
D o not m odify the plug provided. If it will not fit the outlet,
have the proper outlet inslalled by a qualified siectrician
A tem porary adapter m ay be used to connect this plug to
a 2-prong outlet as show n if a properly grotinded three
prong
outlet
is
not
available.
This
tem porary
adapter
should
be
used
only
until
a
properly
grounded
three
prong outlet can be installed by a qualified electrician
The green colored rigid ear, lug or the like, extending
from
the
adapter
m ust
be
connected
to
a
perm anent
ground such as a properly grounded outlet box.
im proper
connection
of
the
equipm ent-grounding
con
ductor can result in a risk of electric shock. The conduc
tor with insulation having an outer surface that is green
w ith or w ithout yellow stripes is the equipm ent-grounding
conductor If repair or replacem ent of the electric cord or
plug is necessary, do not connect the equipm ent-ground
ing conductor to a live term inal
R ated H P
1
Voltage
110-120
Am peres
11 5
H ertz (C ycles)
60
Phase
Single
R PM
3450
R otation of S haft
C ounterclockw ise
WARNING: Do not permit fingers to touch the ter
minals of plug when installing or removing the
plug to or from the outiet.
If the grounding instructions are not com pletely under
stood, or if you are in doubt as to w hether the too! is prop
erly grounded check w ith a qualified electrician or service
personnel.
WARNING: If not properly grounded, this tool can
cause an electrical shock, particularly when used
in damp locations, in proximity to plumbing, or out
of doors, if an electrical shock occurs there is the
potential of a secondary hazard, such as your
hands contacting the sawblade.
Properly
Grounded
3-Prong Outlet
3-Prong Plug
Grounding
Prong
Grounding Lug
3-Prong ^
Make sure this
Is Connected
to a Known
Ground
2-Prong
Outlet
Adapter
N O TE: The adapter illustrated is for use oniy If you