Dell PowerVault NX3000 User Manual
Page 48
48
About Your System
The following
DIMMs should
match
in
geometry:
x,x,...
Invalid memory
configuration. The specified
memory modules do not
match in size, number of
ranks, or number of data
lanes.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines."
The following
DIMMs should
match
in rank
count:
x,x,...
The following
DIMMs should
match in size:
x,x,...
The following
DIMMs should
match
in size
and geometry:
x,x,...
The following
DIMMs should
match
in size
and rank count:
x,x,...
Thermal sensor
not detected on
x
A memory module without a
thermal sensor is installed in
the specified memory slot
Replace the memory module.
See "System Memory."
Time-of-day
clock stopped
Faulty battery or faulty chip. See "Troubleshooting the
Time-of-day not
set - please run
SETUP program
Incorrect Time or Date
settings; faulty system
battery.
Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager." If the
problem persists, replace the
system battery. See "System
Battery."
Table 1-2.
System Messages (continued)
Message
Causes
Corrective Actions