beautypg.com

Dell PowerVault NX3000 User Manual

Page 28

background image

28

About Your System

E1620

Power Supply

# (### W) AC

power error.

Check PSU

cables.

Specified power supply's
AC input is outside of the
allowable range.

Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies."

E1624

Lost power

supply

redundancy.

Check PSU

cables.

The power supply
subsystem is no longer
redundant. If the remaining
power supply fails, the
system will shut down.

See "Troubleshooting
Power Supplies."

E1626

Power Supply

Mismatch.

PSU1 = ### W,

PSU2 = ### W.

The power supplies in the
system are not the same
wattage.

Ensure that power
supplies with matching
wattage are installed. See
the Technical
Specifications outlined in
your system’s Getting
Started Guide.

E1629

Power

required >

PSU wattage.

Check PSU and

config.

The system configuration
requires more power than
the power supplies can
provide, even with
throttling.

Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.

E1710

I/O channel

check error.

Review &

clear SEL.

The system BIOS has
reported an I/O channel
check.

Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.

If the problem persists,
see "Getting Help."

Table 1-1.

LCD Status Messages (continued)

Code

Text

Cause

Corrective Actions